FLASH REQUIRED
This presentation requires a flash plugin for your browser.
Here you can get the latest version.
The family of AT LISA multifocal IOLs is what many cataract or presbyopic patients with or without astigmatism have been waiting for: the chance to enjoy life with only minimal or no support from glasses.
| Lens*** | AT LISA 809M |
AT LISA toric 909M |
|---|---|---|
| Optic Design | Multifocal, aspheric (negative spherical aberration) | Multifocal, aspheric (negative spherical aberration) |
| Material | Hydrophilic acrylic (25 %) with hydrophobic surface | Hydrophilic acrylic (25 %) with hydrophobic surface |
| Optic Diameter | 6.0 mm | 6.0 mm |
| Total Diameter | 11.0 mm | 11.0 mm |
| Haptic Angulation | 0º | 0º |
| Lens Design | Single-Piece, diffractive, +3.75 D add at the IOL plane, MICS | Single-Piece, diffractive, +3.75 D add at IOL plane, toric, MICS |
| Incision Size | 1.5 mm | 1.5 mm |
| Company Labeled A-Constant * | 117.8 | 118.3 |
| Diopter Range | From 0.0 to +32.0 D 0.0 to +32.0 D 0.5 D increment |
From -10.0 to +32.0 D Sphere -10.0 to +32.0 D 0.5 D increment Cylinder +1.0 to +12.0 D 0.5 D increment |
| ACD | 4.85 | 5.14 |
| Implantation in: | Bag | Bag |
| Injector / Cartridge ** | Acri.Shooter A2-2000 / ACM2 (1.5 mm) Single-use injector A6 / *AT.Smart Cartridge Set (1.8 mm) |
Acri.Shooter A2-2000 / ACM2 (1.5 mm) Single-use injector A6 / *AT.Smart Cartridge Set (1.8 mm) For a diopter range outside of +16.0 to +24.0 D sphere with +1 to +3 cylinder, the correct injector / Cartridge will be provided with the IOL. |
* Please refer to our web pages for optimized A-Constants.
** Please refer to our web pages for the most up-to-date references.
*** Please ask your local representative for the current product name used in your country.
| Lens*** | AT LISA 801 |
AT LISA 802 |
|---|---|---|
| Optic Design | Multifocal, aspheric (negative spherical aberration) | Multifocal, aspheric (negative spherical aberration) |
| Material | Hydrophilic acrylic (25 %) with hydrophobic surface | Hydrophilic acrylic (25 %) with hydrophobic surface |
| Optic Diameter | 6.0 mm | 6.0 mm |
| Total Diameter | 12.5 mm | 12.5 mm |
| Haptic Angulation | 0º | 5º |
| Lens Design | Single-Piece, diffractive, +3.75 D add at IOL plane | Three-Piece, diffractive, +3.75 D add at IOL plane |
| Incision Size | 2.2 mm | 2.8 mm |
| Company Labeled A-Constant * | 118 | 118.1 |
| Diopter Range | From 0.0 to + 30.0 D (from + 31.0 to + 40.0 D upon request) 0.0 to + 10.0 D, 1.0 D increments + 10.0 to + 30.0 D,0.5 D increments + 30.0 to + 40.0 D, 1.0 D increments |
From 0.0 to + 30.0 D (from + 31.0 to + 40.0 D upon request) 0.0 to + 10.0 D, 1.0 D increments + 10.0 to + 30.0 D,0.5 D increments + 30.0 to + 40.0 D, 1.0 D increments |
| ACD | 4.97 | 5.02 |
| Implantation in: | Bag | Bag |
| Injector / Cartridge ** | Acri.Shooter A1-2000 / VISCOJECTTM 2.2 Cartridge Set (2.2 mm) VISCOJECTTM 2.2 Cartridge Set (2.2 mm) For a diopter range outside of 0.0 to +30.0 D, the correct injector / cartridge will be provided with the IOL. |
NAVIJECTTM 2.8 -3P Injector Set (up to + 30.0 D) For a diopter range outside of 0.0 to +30.0 D, the correct injector / cartridge will be provided with the IOL. |
* Please refer to our web pages for optimized A-Constants.
** Please refer to our web pages for the most up-to-date references.
*** Please ask your local representative for the current product name used in your country.